Cyber Resilience Act: when you need a notified body

Stefan Hülsiggensen

10 min read

Cyber Resilience Act notified body: which connected products need third-party assessment from December 2027, why standards decide and how to plan now.

Smart home device on a turntable in a radio test chamber

You make Wi-Fi routers, smart door locks or a smartwatch for children outside the EU and want to keep selling them in Europe after 11 December 2027. Under the Cyber Resilience Act, most connected products can be self-assessed, but some need a notified body, an independent organization designated by an EU member state. Here is how to tell which group your product belongs to, why the answer currently hinges on standards that are not yet cited, and what to plan now.

What a notified body does under the Cyber Resilience Act

The Cyber Resilience Act (CRA), Regulation (EU) 2024/2847 (opens in a new tab), sets cybersecurity requirements for hardware and software with a data connection. It applies directly in every member state, mostly from 11 December 2027; its chapter on notified bodies has applied since 11 June 2026 (Article 71(2)).

Before placing a product on the market, you as manufacturer carry out a conformity assessment (Article 13(12)). Article 32 and Annex VIII offer these routes:

Conformity assessment routes under Article 32 CRA
RouteWho assessesWhat happens
Module A, internal controlYou aloneYou check product and vulnerability handling against Annex I and sign the EU Declaration of Conformity
Module B+C, EU-type examinationNotified body for the designThe body examines documentation and specimens, issues a certificate and audits your vulnerability handling
Module H, full quality assuranceNotified body for your quality systemThe body approves and audits your system for design, testing and vulnerability handling
European cybersecurity certificationCertification body under Regulation (EU) 2019/881Only once a delegated act specifies the scheme (Article 27(9)); none adopted as of 9 October 2026
Conformity assessment routes under Article 32 CRA

Default, important or critical: the core functionality decides

Which route you may use depends on the product's core functionality (Articles 7(1) and 8(1)): its main features and technical capabilities, without which it could not meet its intended purpose (Commission guidance C(2026) 5252, point 139). Implementing Regulation (EU) 2025/2392 (opens in a new tab) describes each listed category.

Product categories and the role of a notified body (Articles 7, 8 and 32, Annexes III and IV CRA)
CategoryExamplesNotified body
DefaultProducts whose core functionality is not listed in Annex III or IVNot required; module A always available (Article 32(1))
Important, class IRouters, internet modems, switches; smart locks, home security cameras, baby monitors, alarm systems; smart speakers with a virtual assistant; connected toys that speak, film or track location; health-monitoring wearables and wearables for children under 14; operating systems, VPNsRequired unless cited harmonized standards, common specifications or a certification scheme are applied in full (Article 32(2))
Important, class IIHypervisors, firewalls, intrusion detection systems, tamper-resistant microprocessors and microcontrollersRequired: module B+C or H, or a European cybersecurity certificate once available (Article 32(3))
CriticalHardware devices with security boxes, smart meter gateways, smartcards and secure elementsRequired, until a delegated act prescribes a European cybersecurity certificate (Articles 8(1) and 32(4))
Product categories and the role of a notified body (Articles 7, 8 and 32, Annexes III and IV CRA)

A listed component does not change the category. A device with a Wi-Fi chip or an embedded operating system is not class I for that reason alone (Article 7(1)); the Commission's example is a smartphone (guidance, Example 58). The chip maker is a different case: a Wi-Fi or Bluetooth network controller or adapter placed on the market on its own is a physical network interface of class I (Annex I, point 10, to Implementing Regulation (EU) 2025/2392).

A product has only one core functionality for this purpose. The Commission warns against downplaying functions to escape a stricter procedure, for example where marketing, instructions and technical documentation contradict each other (guidance, points 143 and 144).

Class I products: why harmonized standards decide

For class I, module A is open only if you apply harmonized standards, common specifications or a European cybersecurity certification scheme at assurance level at least substantial in full (Article 32(2)). According to the Commission, the standard must also cover all cybersecurity risks of the core functionality (guidance, point 149). Where you apply it only in part, a notified body assesses the requirements left open.

Only standards whose references are published in the Official Journal give a presumption of conformity (Article 27(1)). They are being drafted under the Commission's request M/606. As of 9 October 2026, no reference to a harmonized standard under the CRA had been published, and no common specification adopted. If that is still the case when your first CRA-compliant units ship, a class I product needs module B+C or H.

Module B+C or module H: what the notified body examines

Module B+C suits manufacturers with few models. You apply to one notified body of your choice with the technical documentation, including your cybersecurity risk assessment and test reports. The body examines the design and specimens, tests or commissions tests and issues an EU-type examination certificate (Annex VIII, Part II, points 2 to 6). It then audits your vulnerability handling periodically, and changes that may affect conformity need an addition to the certificate (points 7 and 8).

Module H suits portfolios with many models or frequent updates (Commission FAQ, section 6.3). The body approves and periodically audits your quality system for design, development, testing and vulnerability handling, and its identification number follows the CE marking (Annex VIII, Part IV; Article 30(4)).

Documentation for the notified body must be in an official language of its member state or one it accepts (Article 31(4)). Fees must take account of the needs of small and medium-sized enterprises (Article 32(6)).

What to do now: a plan for 2026 and 2027

  1. Classify every product by its core functionality and record the result in the technical documentation (Annex VII; guidance, point 144).
  2. Align marketing, manuals and documentation on the same core functionality.
  3. For class I, track the standards and their citation in the Official Journal, with module B+C or H as the fallback.
  4. Choose the module: B+C per model, H for a portfolio with frequent releases.
  5. Shortlist notified bodies in NANDO; member states shall strive to have enough of them by 11 December 2026 (Article 35(2)).
  6. Prepare the evidence: cybersecurity risk assessment, test reports and vulnerability handling, including the software bill of materials (Annex VII, points 2(b), 3 and 6).
  7. Finish before 11 December 2027. Compliance counts per unit: further units of an older model placed on the market from that date must meet the CRA (Commission FAQ, section 7.2).

Example: an Asian smart home brand with three products

An Asian brand sells a smart plug, a home security camera with a hub and a Wi-Fi mesh router in the EU, with firmware updates every quarter.

Classification and route in the example, as of 9 October 2026
ProductCategoryRoute
Smart plug with appDefault: not listed in Annex III or IVModule A
Security camera and hubClass I: hardware that centrally controls the camera is covered too (Annex I, point 17, to Implementing Regulation (EU) 2025/2392)Module B+C or H, unless a cited standard is applied in full
Wi-Fi mesh routerClass I: wireless router (Annex I, point 12)As for the camera
Classification and route in the example, as of 9 October 2026

Because of the frequent releases, the brand chooses module H with one notified body for camera and router. Units placed on the market until 10 December 2027 must still meet the cybersecurity requirements of the Radio Equipment Directive (see our article on EN 18031); EU-type examination certificates on cybersecurity issued under that directive remain valid until 11 June 2028 unless they expire earlier (Article 69(1) CRA).

Common mistakes with notified bodies under the CRA

  • Classifying by components. A Wi-Fi chip does not make the device class I (Article 7(1)).
  • Counting on a standard that is not cited. Only references in the Official Journal give a presumption (Article 27(1)).
  • Applying a standard in part and self-assessing. For class I, the open requirements need a notified body (Article 32(2)).
  • Treating the certificate as final. Audits of vulnerability handling continue, and relevant changes need an addition (Annex VIII, Part II, points 7 and 8).

Conclusion: classify now, book the notified body early

Most connected products will never need a notified body under the Cyber Resilience Act. For routers, smart locks, cameras, connected toys and children's wearables, it depends on harmonized standards; as long as none is cited, plan for module B+C or H. For a wrong conformity assessment procedure, Article 64(3) allows fines of up to 10 million euros or 2% of worldwide annual turnover from 11 December 2027, under rules set by the member states.

The conformity assessment remains your duty as manufacturer (Article 13(12)). An authorized representative under Article 18 CRA may lodge the application with the notified body if the mandate provides for it (Annex VIII, Part II, point 11), but designing the product and drawing up the technical documentation cannot be delegated (Article 18(2)). Our CE marking service helps you, within the agreed scope, identify the applicable acts and standards, coordinate testing and review your technical documentation. For the duty that already applies, see CRA reporting obligations.

How Representa can help

Frequently asked questions

Does every product under the Cyber Resilience Act need a notified body?

No. Products whose core functionality is not listed in Annex III or IV can use internal control (module A). A notified body is required for important products of class II and critical products, and for class I products unless cited harmonized standards, common specifications or a certification scheme are applied in full (Article 32 CRA).

Is a smart home security camera an important product under the CRA?

Yes. Home security cameras are important products of class I (Annex III, point 17, CRA; Annex I, point 17, to Implementing Regulation (EU) 2025/2392). Without a cited harmonized standard applied in full, the manufacturer needs module B+C or H with a notified body.

When can manufacturers use a notified body under the CRA?

The rules on notified bodies have applied since 11 June 2026 (Article 71(2) CRA). A body may act once its notification for the CRA has passed without objection (Article 43(5)); the Commission lists it in NANDO. Member states shall strive to have enough notified bodies by 11 December 2026 (Article 35(2)).

Does a Wi-Fi module make my device an important product?

No. Integrating a product with the core functionality of an Annex III category does not in itself make the final product important (Article 7(1) CRA). A Wi-Fi network controller or adapter placed on the market on its own is itself a physical network interface of class I (Annex I, point 10, to Implementing Regulation (EU) 2025/2392).

How long do cybersecurity certificates under the Radio Equipment Directive remain valid?

EU-type examination certificates on cybersecurity issued under EU harmonization legislation other than the CRA, such as the Radio Equipment Directive, remain valid until 11 June 2028 unless they expire earlier (Article 69(1) CRA).

Upcoming webinar

EU Machinery Regulation, Day One: Can your next machine enter Europe?

  • 16:30 CET · 15:30 UK · 10:30 US Eastern
  • Live online · 30 minutes · Free
See all webinars

More insights

Apply this to your product

Talk to our team: we identify which of these requirements apply to you.

Stefan HülsiggensenFounder and Managing Director